CLZ (vector)

Count leading zero bits (vector)

This instruction counts the number of consecutive zeros, starting from the most significant bit, in each vector element in the source SIMD&FP register, places the result into a vector, and writes the vector to the destination SIMD&FP register.

Depending on the settings in the CPACR_EL1, CPTR_EL2, and CPTR_EL3 registers, and the current Security state and Exception level, an attempt to execute the instruction might be trapped.

Vector
(FEAT_AdvSIMD)

313029282726252423222120191817161514131211109876543210
0Q101110size100000010010RnRd
Uopcode

Encoding

CLZ <Vd>.<T>, <Vn>.<T>

Decode for this encoding

if !IsFeatureImplemented(FEAT_AdvSIMD) then EndOfDecode(Decode_UNDEF); if size == '11' then EndOfDecode(Decode_UNDEF); constant integer d = UInt(Rd); constant integer n = UInt(Rn); constant integer esize = 8 << UInt(size); constant integer datasize = 64 << UInt(Q); constant integer elements = datasize DIV esize;

Assembler Symbols

<Vd>

Is the name of the SIMD&FP destination register, encoded in the "Rd" field.

<T>

Is an arrangement specifier, encoded in size:Q:

size Q <T>
00 0 8B
00 1 16B
01 0 4H
01 1 8H
10 0 2S
10 1 4S
11 x RESERVED
<Vn>

Is the name of the SIMD&FP source register, encoded in the "Rn" field.

Operation

CheckFPAdvSIMDEnabled64(); constant bits(datasize) operand = V[n, datasize]; bits(datasize) result; for e = 0 to elements-1 constant integer count = CountLeadingZeroBits(Elem[operand, e, esize]); Elem[result, e, esize] = count<esize-1:0>; V[d, datasize] = result;

Operational information

If PSTATE.DIT is 1:


Internal version only: aarchmrs v2024-12_rel, pseudocode v2024-12_rel ; Build timestamp: 2024-12-15T22:18

Copyright © 2010-2024 Arm Limited or its affiliates. All rights reserved. This document is Non-Confidential.